Methods of calculating the partial derivatives of the electron radiation dose which is measured with dosimetric wedge
Keywords:
electron radiation, depth-dose distribution, numerical methods, semi-empirical model, empirical formulas
Abstract
In the work, the numerical methods of determining the standard characteristics of the electron radiation depth-dose distribution by processing the measurement results are compared with the empirical formulas linking the same characteristics with the electrons energy. The comparison results allow authors to estimate the accuracy of methods used in radiation technologies to determine the characteristics of electron radiation energy.
Downloads
Download data is not yet available.
References
ICRU REPORT 35. Radiation dosimetry: electron beams with energies between 1 and 50MeV, 1984. – 160 p.
ISO/ASTM Standard 51649, Practice for dosimetry in an e-beam facility for radia¬tion processing at energies between 300 keV and 25 MeV. Annual Book of ASTM Standards. Vol. 2005.12.02.
V. T. Lazurik, G. Popov, S. Salah, Z. Zimek. Evaluation of accuracy of the methods for obtaining spatial characteristics of electron radiation depth-dose distribution.// Bulletin of V. Karazin Kharkiv National University, –2015. –Series «Math. Modelling. Information Technology. Automated Control Systems», Issue 28. – p. 126-139.
V. T. Lazurik, V.M. Lazurik, G. Popov, Yu. Rogov, Z. Zimek. Information System and Software for Quality Control of Radiation Processing / IAEA: Collaborating Center for Radiation Processing and Industrial Dosimetry, Warsaw: Poland. 2011. – 220 p.
V. M. Lazurik, T. Tabata, V. T. Lazurik. A Database for Electron-Material Interactions // Radiation Physics and Chemistry. – 2001. – Vol.60. – P. 161-162.
ISO/ASTM Standard 51649, Practice for dosimetry in an e-beam facility for radia¬tion processing at energies between 300 keV and 25 MeV. Annual Book of ASTM Standards. Vol. 2005.12.02.
V. T. Lazurik, G. Popov, S. Salah, Z. Zimek. Evaluation of accuracy of the methods for obtaining spatial characteristics of electron radiation depth-dose distribution.// Bulletin of V. Karazin Kharkiv National University, –2015. –Series «Math. Modelling. Information Technology. Automated Control Systems», Issue 28. – p. 126-139.
V. T. Lazurik, V.M. Lazurik, G. Popov, Yu. Rogov, Z. Zimek. Information System and Software for Quality Control of Radiation Processing / IAEA: Collaborating Center for Radiation Processing and Industrial Dosimetry, Warsaw: Poland. 2011. – 220 p.
V. M. Lazurik, T. Tabata, V. T. Lazurik. A Database for Electron-Material Interactions // Radiation Physics and Chemistry. – 2001. – Vol.60. – P. 161-162.
Published
2016-06-24
How to Cite
Lazurik, V. T., Popov, G. F., Salah, S., & Zimek, Z. (2016). Methods of calculating the partial derivatives of the electron radiation dose which is measured with dosimetric wedge. Bulletin of V.N. Karazin Kharkiv National University, Series «Mathematical Modeling. Information Technology. Automated Control Systems», 30, 59-68. Retrieved from https://periodicals.karazin.ua/mia/article/view/6571
Issue
Section
Статті