DETERMINATION OF ELECTRON BEAM PARAMETERS ON RADIATIONTECHNOLOGICAL FACILITY FOR SIMULATION OF RADIATION PROCESSING
Анотація
of two-parametric fitting of semi-empirical model for the depth-dose curves (DDC) of electrons beam. The measurement of DDC of electrons into standard dosimetric wedge were performed in the process of radiation sterilization of medical devices on the radiation facility with EB accelerator into INCT, Warsaw, Poland. It was shown that satisfactory agreement between the measurement results and simulation of the DDC of electrons beam with using PFSEM method is observed.
Завантаження
Посилання
ISO/ASTM Standard 51649, Practice for dosimetry in an e-beam facility for radiation processing at energies between 300 keV and 25 MeV / Annual Book of ASTM Standards. – Vol. 12.02 (2005).
Lisanti T.F. Calculating electron range values mathematically // Radiation Physics and Chemistry. – 2004. – Vol. 71. – Р. 581 – 584.
Cleland M.R., Lisanti T.F., Gallowey R.A. Comparisons of Monte Carlo and ICRU electron energy vs. range equations // Radiation Physics and Chemistry. – 2004. – Vol. 71. – Р. 585 –589.
Lazurik V.T., Pochynok A.V. Dosimetry of electrons on the base of computer modeling the depth-dose distribution of irradiation // Journal of Kharkiv University. Mathematical modeling. Information technologies series. – 2010. – No.925. – P.114 – 122.
Pochynok A.V., Lazurik V.T., Sarukhanyan G.E. The parametric method of the determination of electron energy on the data obtained by the method of a dosimetric wedge //Bulletin Kherson National Technical University. – 2012. – Vol. 2(45). – P.298-302.
Lazurik V.M., Tabata T., Lazurik V.T. A Database for Electron-Material Interactions // Radiation Physics and Chemistry. – 2001. – Vol.60. – P. 161-162.
GEX Corporation. The Dosimetry company. http://gexcorporation.com/
Lazurik V.T., Lazurik V.M., Popov G., Rogov Yu., Zimek Z. Information System and Software for Quality Control of Radiation Processing // IAEA: Collaborating Center for Radiation Processing and Industrial Dosimetry, Warsaw: Poland. – 2011. – 220 p.
Bigolas J., Kulinski S., Maciszewski W., Pachan M., Plawski E, Zimek Z. Current approach to design of high-power electron accelerators to match actual requirements of radiation technology in Poland // Radiation Physics and Chemistry. – 2001. – Vol. 60. – P.161-162.
Miller A. Polystyrene calorimeter for electron beam dose measurements // Radiation Physics and Chemistry. – 1993. – Vol.46. – Р. 1243–1246.
National Physical Laboratory, Teddington, Middlesex, UK [www.npl.co.uk]
Автори, які публікуються у цьому журналі, погоджуються з наступними умовами:
- Автори залишають за собою право на авторство своєї роботи та передають журналу право першої публікації цієї роботи на умовах ліцензії Creative Commons Attribution License, котра дозволяє іншим особам вільно розповсюджувати опубліковану роботу з обов'язковим посиланням на авторів оригінальної роботи та першу публікацію роботи у цьому журналі.
- Автори мають право укладати самостійні додаткові угоди щодо неексклюзивного розповсюдження роботи у тому вигляді, в якому вона була опублікована цим журналом (наприклад, розміщувати роботу в електронному сховищі установи або публікувати у складі монографії), за умови збереження посилання на першу публікацію роботи у цьому журналі.
- Політика журналу дозволяє і заохочує розміщення авторами в мережі Інтернет (наприклад, у сховищах установ або на особистих веб-сайтах) рукопису роботи, як до подання цього рукопису до редакції, так і під час його редакційного опрацювання, оскільки це сприяє виникненню продуктивної наукової дискусії та позитивно позначається на оперативності та динаміці цитування опублікованої роботи (див. The Effect of Open Access).