Clinical Commissioning and Dosimetric Verification of the Raystation Treatment Planning System

Keywords: RayStation, Commissioning, Dosimetric Verification

Abstract

Background: The software used by treatment planning systems (TPS) plays an important role for treatments using radiation. The accuracy of the calculated dose in radiation treatments depends on the assumptions made by the TPS. In this study, we summarize our methods and results regarding clinical commissioning of the basic functions needed for photon therapy. Materials and Method: Measurements were obtained for the 6 and 15 MV photon energies obtained from the Siemens Artiste linear accelerator device. Important data such as percent deep dose, profile and output measurements were taken in the water phantom and transferred to the RayStation Treatment Planning System. Results: When the absolute dose values calculated by the RayStation TPS are compared with the water phantom data, the differences obtained are less than 3%. When the 2-dimensional quality control of asymmetrical areas and patients with IMRT plan was controlled by gamma analysis method, the gamma rate was more than 95%. Conclusion: One of the most important quality control tests is TPS acceptance tests, which must be performed before clinical use. In this study, in which we checked the basic dose measurement and patient planning, it was seen that the RayStation TPS can be used in patient treatment for clinical use. The doses calculated by the RayStation TPS were found to be reliable and within the expected accuracy range. These results are sufficient for the application of 3-dimensional conformal radiotherapy (3D-CRT) and IMRT technique.

Downloads

Download data is not yet available.

References

C. Bäumer, D. Geismar, B. Koska, P.H. Kramer, J. Lambert, M. Lemke, S. Plaude, L. Pschichholz, S. Qamhiyeh, A. Schiemann, B. Timmermann, and X. Vermeren, Physica Medica, 43, 15–24 (2017), https://doi.org/10.1016/j.ejmp.2017.09.136

Investigation of an Accidental Exposure of Radiotherapy Patients in Panama. (IAEA, Vienna, 2001), https://www-pub.iaea.org/MTCD/Publications/PDF/Pub1114_scr.pdf

Lessons Learned from Accidental Exposures in Radiotherapy, Safety Reports Series No. 17, (IAEA, Vienna, 2000), http://www-pub.iaea.org/MTCD/Publications/PDF/Pub1084_web.pdf

L. Rutonjski, B. Petrović, M. Baucal, M. Teodorović, O. Čudić, E. Gershkevitsh, and J. Izewska, Radiation Oncology, 7, 155 (2012), https://doi.org/10.1186/1748-717x-7-155

Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer, Technical Reports Series No. 430, (IAEA, Vienna, 2004), http://www-pub.iaea.org/MTCD/Publications/PDF/TRS430_web.pdf

Commissioning of radiotherapy treatment planning systems: testing for typical external beam treatment techniques, TECDOC 1583, (IAEA, Vienna, 2008), https://www-pub.iaea.org/MTCD/Publications/PDF/te_1583_web.pdf

American Association of Physicists in Medicine Radiation Therapy Committee Task Group 23 “Radiation Treatment Planning Dosimetry Verification” (AIP, New York, 1995), https://www.aapm.org/pubs/reports/RPT_55.pdf

G.J. Kutcher, L. Coia, M. Gillin, W.F. Hanson, S. Leibel, R.J. Morton, et al, Med. Phys. 21(4), 581 (1994); https://doi.org/10.1118/1.597316

D. Bodensteiner, Medical Dosimetry, 43, 168 (2018), https://doi.org/10.1016/j.meddos.2018.02.013

J. Saini, N. Cao, S.R. Bowen, M. Herrera, D. Nicewonger, T. Wong, and C.D. Bloch, Int. J. Particle Therapy, 3(1), 51 (2016), https://doi.org/10.14338/IJPT-16-0000.1

B. Mzenda, K. Mugabe, R. Sims, G. Godwin, and D. Loria, Modeling and dosimetric performance evaluation of the RayStation treatment planning system. J. Appl. Clin. Med. Phys. 15(5), 29 (2014), https://doi.org/10.1120/jacmp.v15i5.4787

B. Fraass, K. Doppke, M. Hunt, G. Kutcher, G. Starkschall, R. Stern, and J. Van Dyke, Med. Phys. 25, 1773 (1998), https://doi.org/10.1118/1.598373

B. Mijnheer, A. Olszewska, C. Fiorino, et al, Quality assurance of treatment planning systems. Practical examples for non-IMRT photon beams. (ESTRO, Brussels, 2005). ESTRO Booklet no. 7, in: 8th Biennial ESTRO Meeting on Physics and Radiation Technology for Clinical Radiotherapy, Radiotherapy and Oncology, 73, Suppl. 1, S417, (2004), https://doi.org/10.1016/s0167-8140%2804%2982857-3

G.A. Ezzell, J.W. Burmeister, N. Dogan, T.J. LoSasso, J.G. Mechalakos, D. Mihailidis, et al, Med. Phys. 36(11), 5359 (2009), https://doi.org/10.1118/1.3238104

Absorbed dose determination in external beam radiotherapy. An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water Technical Report Series 398, (IAEA, Vienna, 2000), http://www-naweb.iaea.org/nahu/DMRP/documents/CoP_V12_2006-06-05.pdf

Published
2021-12-10
Cited
How to Cite
Tuğrul, T. (2021). Clinical Commissioning and Dosimetric Verification of the Raystation Treatment Planning System. East European Journal of Physics, (4), 114-119. https://doi.org/10.26565/2312-4334-2021-4-13