Clinical Commissioning and Dosimetric Verification of the Raystation Treatment Planning System
Abstract
Background: The software used by treatment planning systems (TPS) plays an important role for treatments using radiation. The accuracy of the calculated dose in radiation treatments depends on the assumptions made by the TPS. In this study, we summarize our methods and results regarding clinical commissioning of the basic functions needed for photon therapy. Materials and Method: Measurements were obtained for the 6 and 15 MV photon energies obtained from the Siemens Artiste linear accelerator device. Important data such as percent deep dose, profile and output measurements were taken in the water phantom and transferred to the RayStation Treatment Planning System. Results: When the absolute dose values calculated by the RayStation TPS are compared with the water phantom data, the differences obtained are less than 3%. When the 2-dimensional quality control of asymmetrical areas and patients with IMRT plan was controlled by gamma analysis method, the gamma rate was more than 95%. Conclusion: One of the most important quality control tests is TPS acceptance tests, which must be performed before clinical use. In this study, in which we checked the basic dose measurement and patient planning, it was seen that the RayStation TPS can be used in patient treatment for clinical use. The doses calculated by the RayStation TPS were found to be reliable and within the expected accuracy range. These results are sufficient for the application of 3-dimensional conformal radiotherapy (3D-CRT) and IMRT technique.
Downloads
References
C. Bäumer, D. Geismar, B. Koska, P.H. Kramer, J. Lambert, M. Lemke, S. Plaude, L. Pschichholz, S. Qamhiyeh, A. Schiemann, B. Timmermann, and X. Vermeren, Physica Medica, 43, 15–24 (2017), https://doi.org/10.1016/j.ejmp.2017.09.136
Investigation of an Accidental Exposure of Radiotherapy Patients in Panama. (IAEA, Vienna, 2001), https://www-pub.iaea.org/MTCD/Publications/PDF/Pub1114_scr.pdf
Lessons Learned from Accidental Exposures in Radiotherapy, Safety Reports Series No. 17, (IAEA, Vienna, 2000), http://www-pub.iaea.org/MTCD/Publications/PDF/Pub1084_web.pdf
L. Rutonjski, B. Petrović, M. Baucal, M. Teodorović, O. Čudić, E. Gershkevitsh, and J. Izewska, Radiation Oncology, 7, 155 (2012), https://doi.org/10.1186/1748-717x-7-155
Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer, Technical Reports Series No. 430, (IAEA, Vienna, 2004), http://www-pub.iaea.org/MTCD/Publications/PDF/TRS430_web.pdf
Commissioning of radiotherapy treatment planning systems: testing for typical external beam treatment techniques, TECDOC 1583, (IAEA, Vienna, 2008), https://www-pub.iaea.org/MTCD/Publications/PDF/te_1583_web.pdf
American Association of Physicists in Medicine Radiation Therapy Committee Task Group 23 “Radiation Treatment Planning Dosimetry Verification” (AIP, New York, 1995), https://www.aapm.org/pubs/reports/RPT_55.pdf
G.J. Kutcher, L. Coia, M. Gillin, W.F. Hanson, S. Leibel, R.J. Morton, et al, Med. Phys. 21(4), 581 (1994); https://doi.org/10.1118/1.597316
D. Bodensteiner, Medical Dosimetry, 43, 168 (2018), https://doi.org/10.1016/j.meddos.2018.02.013
J. Saini, N. Cao, S.R. Bowen, M. Herrera, D. Nicewonger, T. Wong, and C.D. Bloch, Int. J. Particle Therapy, 3(1), 51 (2016), https://doi.org/10.14338/IJPT-16-0000.1
B. Mzenda, K. Mugabe, R. Sims, G. Godwin, and D. Loria, Modeling and dosimetric performance evaluation of the RayStation treatment planning system. J. Appl. Clin. Med. Phys. 15(5), 29 (2014), https://doi.org/10.1120/jacmp.v15i5.4787
B. Fraass, K. Doppke, M. Hunt, G. Kutcher, G. Starkschall, R. Stern, and J. Van Dyke, Med. Phys. 25, 1773 (1998), https://doi.org/10.1118/1.598373
B. Mijnheer, A. Olszewska, C. Fiorino, et al, Quality assurance of treatment planning systems. Practical examples for non-IMRT photon beams. (ESTRO, Brussels, 2005). ESTRO Booklet no. 7, in: 8th Biennial ESTRO Meeting on Physics and Radiation Technology for Clinical Radiotherapy, Radiotherapy and Oncology, 73, Suppl. 1, S417, (2004), https://doi.org/10.1016/s0167-8140%2804%2982857-3
G.A. Ezzell, J.W. Burmeister, N. Dogan, T.J. LoSasso, J.G. Mechalakos, D. Mihailidis, et al, Med. Phys. 36(11), 5359 (2009), https://doi.org/10.1118/1.3238104
Absorbed dose determination in external beam radiotherapy. An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water Technical Report Series 398, (IAEA, Vienna, 2000), http://www-naweb.iaea.org/nahu/DMRP/documents/CoP_V12_2006-06-05.pdf
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).