SINGLE AND DUAL-POINTING DEVICE FOR MOVING THE SAMPLE LU-40 KIPT

  • A. N. Vodin National Scientific Centre “Kharkiv Institute of Physics and Technology”
  • V. T. Bykov National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • V. A. Kushnir National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • M. S. Malovitza V.N. Karazin Kharkiv National University 4, Svobody sq, 61022, Kharkiv, Ukraine
  • S. N. Olejnik National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • G. E. Tuller National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • A. V. Tertichniy National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine

Abstract

Developed two electro-mechanical device with remote control, designed to move the samples one and two dimensions in a highbackground radiation. Samples movement carried in mechanical block by stepper motor with holding torque 5.6 kgf·cm and angle precision 1.8°/step. Motor control and control of samples coordinates implements by dint on electronic block, based on PIC16f76 microcontroller and Usart-RS485 interface converter based on Max 485 microchip. Devices can move objects weighing up to 100 g with an accuracy of 0.5 mm. The testing of the two-coordinate device in experiments on electron beam accelerator LU-40 KIPT have been held. The two-dimensional distribution of relative density of the flow distribution of brake γ-rays have been measured by ionization detector.

Downloads

Author Biography

A. V. Tertichniy, National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine

 

 

References

http://www.focus-nuclear.com/pdf/TP_AUMA.pdf.

http://www.zpa-pecky.cz/electric-actuators/multi-turn/moa-oc.htm?lang=en.

http://www.bernardcontrols.com/en/valve-actuator-market/nuclear-energy/.

Vodin A.N., Olejnik S.N., Tuller G.Je., Tertichnyj A.V. Dvuh-koordinatnaja sistema dlja peremeshhenija datchika izmerenija plotnosti potoka γ-kvantov // Tezisy dokladov na HI Konferencii po fizike vysokih energij, jadernoj fizike i uskoriteljam, Har'kov, 11-15 marta 2013 g. – S.116.

Ayzatskiy M.I., Borts B.V., Vodin A.N. at all. NSC KIPT Neutron Source // Problems of Atomic Science and Technology, series Nuclear Physics Investigations. – 2012. – No.3(79). – P.3-9.

L297 Stepper Motor Controller Datasheet http://www.st.com/st-webui/static/active/en/resource/technical/document/datasheet/CD00000063.pdf

L298 Dual Full Bridge Driver Datasheet http://www.st.com/st-webui/static/active/en/fragment/website_building_block/site_media/icon/pdf_icon_large.jpg

Pic16f7x 28/40-pin, 8-bit Cmos Flash Microcontrollers DataSheethttp://ww1.microchip.com/downloads/en/DeviceDoc/30325b.pdf

Lovygin A.A., Teverovskij L.V. Sovremennyj stanok s ChPU i CAD/CAM-sistema. – DMK-Press, 2012. – 279s.

Pabla B.S., Adithan M. CNC Machines. – New Age International, 1994. – 107p.

Published
2016-04-23
Cited
How to Cite
Vodin, A. N., Bykov, V. T., Kushnir, V. A., Malovitza, M. S., Olejnik, S. N., Tuller, G. E., & Tertichniy, A. V. (2016). SINGLE AND DUAL-POINTING DEVICE FOR MOVING THE SAMPLE LU-40 KIPT. East European Journal of Physics, 3(1), 72-76. https://doi.org/10.26565/2312-4334-2016-1-08