SINGLE AND DUAL-POINTING DEVICE FOR MOVING THE SAMPLE LU-40 KIPT

  • A. N. Vodin National Scientific Centre “Kharkiv Institute of Physics and Technology”
  • V. T. Bykov National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • V. A. Kushnir National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • M. S. Malovitza V.N. Karazin Kharkiv National University 4, Svobody sq, 61022, Kharkiv, Ukraine
  • S. N. Olejnik National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • G. E. Tuller National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine
  • A. V. Tertichniy National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine

Abstract

Developed two electro-mechanical device with remote control, designed to move the samples one and two dimensions in a highbackground radiation. Samples movement carried in mechanical block by stepper motor with holding torque 5.6 kgf·cm and angle precision 1.8°/step. Motor control and control of samples coordinates implements by dint on electronic block, based on PIC16f76 microcontroller and Usart-RS485 interface converter based on Max 485 microchip. Devices can move objects weighing up to 100 g with an accuracy of 0.5 mm. The testing of the two-coordinate device in experiments on electron beam accelerator LU-40 KIPT have been held. The two-dimensional distribution of relative density of the flow distribution of brake γ-rays have been measured by ionization detector.

Downloads

Download data is not yet available.

Author Biography

A. V. Tertichniy, National Scientific Centre “Kharkiv Institute of Physics and Technology” 1, Akademichna st., 61108, Kharkiv, Ukraine

 

 

References

http://www.focus-nuclear.com/pdf/TP_AUMA.pdf.

http://www.zpa-pecky.cz/electric-actuators/multi-turn/moa-oc.htm?lang=en.

http://www.bernardcontrols.com/en/valve-actuator-market/nuclear-energy/.

Vodin A.N., Olejnik S.N., Tuller G.Je., Tertichnyj A.V. Dvuh-koordinatnaja sistema dlja peremeshhenija datchika izmerenija plotnosti potoka γ-kvantov // Tezisy dokladov na HI Konferencii po fizike vysokih energij, jadernoj fizike i uskoriteljam, Har'kov, 11-15 marta 2013 g. – S.116.

Ayzatskiy M.I., Borts B.V., Vodin A.N. at all. NSC KIPT Neutron Source // Problems of Atomic Science and Technology, series Nuclear Physics Investigations. – 2012. – No.3(79). – P.3-9.

L297 Stepper Motor Controller Datasheet http://www.st.com/st-webui/static/active/en/resource/technical/document/datasheet/CD00000063.pdf

L298 Dual Full Bridge Driver Datasheet http://www.st.com/st-webui/static/active/en/fragment/website_building_block/site_media/icon/pdf_icon_large.jpg

Pic16f7x 28/40-pin, 8-bit Cmos Flash Microcontrollers DataSheethttp://ww1.microchip.com/downloads/en/DeviceDoc/30325b.pdf

Lovygin A.A., Teverovskij L.V. Sovremennyj stanok s ChPU i CAD/CAM-sistema. – DMK-Press, 2012. – 279s.

Pabla B.S., Adithan M. CNC Machines. – New Age International, 1994. – 107p.

Published
2016-04-23
Cited
How to Cite
Vodin, A. N., Bykov, V. T., Kushnir, V. A., Malovitza, M. S., Olejnik, S. N., Tuller, G. E., & Tertichniy, A. V. (2016). SINGLE AND DUAL-POINTING DEVICE FOR MOVING THE SAMPLE LU-40 KIPT. East European Journal of Physics, 3(1), 72-76. https://doi.org/10.26565/2312-4334-2016-1-08