The relative retention time variability evaluation for flavonoids retention on C18 chromatography columns

  • I. V. Kudris V.N. Karazin Kharkiv National University
  • Artem Yu. Kulikov V.N. Karazin Kharkiv National University
  • O. S. Chernyshova V.N. Karazin Kharkiv National University
Keywords: relative retention time, variability, HPLC, octadecyl silica sorbent

Abstract

In this study the variability of the relative retention times (RRT) for the components of the flavonoids model mixture have been investigated by using 7 different chromatographic columns with octadecilsilica sorbent (C18). It was founded, that the RRT variability depends on the choice of the standard peak, and they cannot be used for substances identification on the chromatogram. The using of several substances in one chromatogram as standard for RRT calculation does not lead to considerable decreasing in RRT variability.

Downloads

Download data is not yet available.

References

Derjavna Farmakopeya Ukrai`ni. 1-e vid. Derjavne pi'dprie''mstvo «naukovo-ekspertniy far-makopeyniy centr». Harki'v: RERI'G, 2001. S. 556. [in Ukranian]

United States Pharmacopoeia, 35th edn. The United States Pharmacopoeia Convention Inc, Rockville MD, 2012. P. 4780.

European Pharmacopoeia 7th edn. Council of Europe: France, Strasbourg, 2010. P. 3310.

Snyder L. R., Kirkland J.J., Dolan J. W. Introduction to Modern Liquid Chromatography, 3rd Edition. John Wiley & Sons: New York, 2012. P. 912.

Dehouck P., Visky D., Kovács Z., Noszál B., Adamsa E., Hoogmartensa J. Uncertainty Re-lated to the Use of Relative Retention Times in Pharmaceutical Analysis. LCGC Europe. 2003, November, 1–8.

Lopez L.A., Rutan S.C. Comparision of methods for characterization of reversed-phase liquid chromatographic selectivity. J. Chromatogr. A. 2002, 965, 301–314.

Kele M., Guiochon G. Repeatability and reproducibility of retention data and band profiles on six batches of monolithic columns. J. Chromatogr. A. 2002, 960 (1-2), 19–49.

Kele M., Guiochon G. Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columns: III. Results obtained with Kromasil C18 col-umns. J. Chromatogr. A. 1999, 855 (2), 423–453.

Snyder L.R. Maximum resolution per unit time in liquid-solid absorption chromatography. Separation on column vs. thin layer. Anal. Chem. 1967, 39, 705–709.

Zenkevich I.G., Kosman V.M. Otnositel'noe poglosch'enie pri razny'h dlinah voln - dopol-nitel'ny'y UF-spektral'ny'y parametr dlya identifikacii organicheskih soedineniy v obrasch'eno-fazovoy HELC. Jurn. analit himii. 1996, 51 (8), 870 – 874. [in Russian]

Published
2014-09-03
Cited
How to Cite
Kudris, I. V., Kulikov, A. Y., & Chernyshova, O. S. (2014). The relative retention time variability evaluation for flavonoids retention on C18 chromatography columns. Kharkiv University Bulletin. Chemical Series, (23), 73-80. https://doi.org/10.26565/2220-637X-2014-23-09