Sonoluminescent spectroscopy in the automated system of efficient and safe work of vacuum-evaporating apparatus

Authors

DOI:

https://doi.org/10.26565/2220-637X-2013-22-26

Keywords:

sodium and potassium chlorides, contents determination, vacuum-evaporating device, sonoluminescent spectroscopy

Abstract

The possibility of using the sonolumineacent spectroscopy in the automated system of efficient work of vacuum-evaporating apparatus has been shown. The relative standard deviation does not exceed 0.05 for the content of sodium chloride and 0.08 for the content of potassium chloride. This is worse than the gravimetric determination (0.01) but better than the atomic absorption spectrometry determination (0.11 and 0.12 respectively).

References

Furman A.A., Bel'dы M. P., Sokolov Y.D. Povarennaya sol'. Proyzvodstvo y prymenenye v khymycheskoy promыshlennosty.–M.: Khymyya, 1989.– 272 s.

Furman A.A., Shraybman S.S. Pryhotovlenye y ochystka rassola.–M.: Khymyya, 1966.– 232 s.

Baklanova E.A., Chmylenko F.A., Sonolyumynestsentnaya spektroskopyya – novыy perspektyvnыy metod analyza // Yzvestyya vuzov. Khymyya y khymycheskaya tekhnolo-hyya.-2005.-T.48, № 1. – S. 3–6.

Frydman V.M. Ul'trazvukovaya khymycheskaya apparatura.– M. : Mashyno-stroenye, 1967. – 211 s.

Chmylenko F.A., Baklanov A.N. Ul'trazvuk v analytycheskoy khymyy. Teoryya y praktyka. - Dnepropetrovsk: yzd-vo Dnepropetrovskoho hosunyversyteta, 2001- 224 s.

Ul'trazvuk. Malen'kaya эntsyklopedyya / Hl.red. Y.P. Holyamyna – M.: Sov. эntsykl., 1979.– 400 s.

Baklanov O.M., Avdyeyenko A.P., Chmylenko F.O., Baklanova L.V. Analitychna khimiya kukhonnoyi soli ta rozsoliv.- Kramators'k, 2011.- 284 s.

Downloads

Published

2013-12-20

How to Cite

Sonoluminescent spectroscopy in the automated system of efficient and safe work of vacuum-evaporating apparatus. (2013). V. N. Karazin Kharkiv National University Bulletin. Chemical Series, 22, 220-224. https://doi.org/10.26565/2220-637X-2013-22-26