Justification of a High-Energy Regime for Water Disinfection by an Electron Beam

Authors

DOI:

https://doi.org/10.26565/2312-4334-2025-3-46

Keywords:

Water disinfection, Electron beam, Bremsstrahlung, Induced activity, Photonuclear reactions, Computer simulation, Sub-threshold energy

Abstract

The challenge of providing safe and clean drinking water requires reliable disinfection methods. Electron beam processing is a promising technology, but its industrial application is often limited by regulatory constraints, which typically cap the electron energy at 10 MeV to prevent induced radioactivity. This paper presents a theoretical justification for the radiological safety of using a higher, sub-threshold energy regime. This paper proposes operating in the 10–15.6 MeV range (using 14.9 MeV as a case study) and demonstrate that this approach allows for the treatment of significantly thicker water layers compared to the standard 10 MeV regime, while ensuring radiological safety. A comprehensive numerical model was used to simulate the process, calculating the bremsstrahlung photon spectrum and the induced activity from potential photonuclear reactions. A quantitative analysis of induced activity was performed for the main components of water (16O, 2H) and typical trace impurities according to Ukrainian standards (DSanPiN 2.2.4-171-10). The analysis proves that the induced radioactivity is negligible. The primary activation channel on oxygen is  energetically forbidden, and the activity from trace elements is short-lived and falls far below the intervention levels set by Ukrainian radiation safety norms (NRBU-97). This work provides a strong physics-based rationale that a high-energy, sub-threshold regime is radiologically safe, which allows for a reconsideration of existing energy limitations in the design of electron beam water treatment facilities.

References

J.W.T. Spinks, and R.J. Woods, An Introduction to Radiation Chemistry, 3rd ed. (Wiley-Interscience, New York, 1990).

State Sanitary Norms and Rules DSanPiN 2.2.4-171-10, Hygienic requirements for drinking water intended for human consumption, (Kyiv, 2010). (in Ukrainian).

Radiation Safety Standards of Ukraine (NRBU-97), Normy radiatsiinoi bezpeky Ukrainy [Radiation Safety Standards of Ukraine], (Kyiv, 1997). (in Ukrainian).

Koning, A., Hilaire, S. Goriely, S. TALYS: modeling of nuclear reactions. Eur. Phys. J. A 59, 131 (2023). https://doi.org/10.1140/epja/s10050-023-01034-3

IAEA-TECDOC-1570, ”Radiation Treatment for Disinfection of Water and Wastewater,” (International Atomic Energy Agency, Vienna, 2008).

G. Van Rossum, and F. L. Drake, Python 3 Reference Manual (CreateSpace, Scotts Valley, CA, 2009).

C.R. Harris, et al., ”Array programming with NumPy,” Nature, 585, 357-362 (2020). https://doi.org/10.1038/s41586-020-2649-2

J.D. Hunter, ”Matplotlib: A 2D graphics environment,” Computing in Science & Engineering, 9, 90-95 (2007). https://doi.org/10.1109/MCSE.2007.55

M.J. Berger, J.S. Coursey, M.A. Zucker, and J. Chang, “ESTAR: Stopping-Power and Range Tables for Electrons,” National Institute of Standards and Technology, Gaithersburg, MD. [Online]. Available: https://www.nist.gov/pml/stopping-power-range-tables-electrons-protons-and-helium-ions

L. I. Schiff, ”Energy-Angle Distribution of Thin Target Bremsstrahlung,” Physical Review, 83, 252 (1951). https://doi.org/10.1103/PhysRev.83.252

F. H. Attix, Introduction to Radiological Physics and Radiation Dosimetry (Wiley-VCH, 2004).

K. S. Krane, Introductory Nuclear Physics (John Wiley & Sons, 1988).

Downloads

Published

2025-09-08

How to Cite

Justification of a High-Energy Regime for Water Disinfection by an Electron Beam. (2025). East European Journal of Physics, 3, 431-435. https://doi.org/10.26565/2312-4334-2025-3-46