Amperometric chemosensors for ammonium ions detection

Authors

  • N. E. Stasyuk Institute of Cell Biology NAS of Ukraine
  • G. Z. Gaida Institute of Cell Biology NAS of Ukraine
  • M. V. Gonchar Institute of Cell Biology NAS of Ukraine
  • E. P. Kovalchuk Institute of Cell Biology NAS of Ukraine

DOI:

https://doi.org/10.26565/2220-637X-2012-21-28

Keywords:

conducting polymers, polyaniline, polypyrrole, amperometric chemosensor, ammonium ions

Abstract

Polymeric tapes of polypyrrole, polyaniline and copper (I) oxide were synthesized on the surface of the electrodes by the method of electrochemical polymerization. The pickoff of amperometric touchcontrol is formed for determination of ammonium ions in solution. Electrochemical activity of constructed chemosensors was explored by cyclic voltamperometry.

References

Karakus E., Pekyardimci S., Esma K. Artif. Cells Blood Substit. Immobil. Biotechnol. 2005. V. 33, No. 3. P. 329-341.

Rao P.S., Subrahmanya S., Sathyanarayana D.N. Synth. Metals. 2002. V.128. P. 311-316.

Setti L., Fraleoni-Morgera A., Ballarin B., Filippini A., Frascaro D., Piana C., Biosens. Bio-electron. 2005. V. 20. P.2019-2026.

Shih Y.T., Huang H.J. Anal. Chim. Acta. 1999. V. 392. P.143-150.

Chaubey A., Pande K.K., Malhotra B.D. Anal. Sci. 2003. V.19, No. 11. P.1477-1480.

Gupta B., Singh S., Mohan S., Prakash R. In-Tech: Biosensors. 2010. P. 93-114.

More P.S., Khollam Y.B., Deshpande S.B. Mat. Let. 2003. V.58. P.205-210.

Kar S., Pal B.N., Chandhuri S., Chakravorty D. J. Phys. Chem. 2006. V.110. P. 4605-4611.

Galatsis K., Li Y.X., Wlodarski W., Comini E., Sberveglieri G., Cantalini C. Santucci S., Pas-sacantando M. Sens. Actuator. B: Chem. 2002. V.83. P.276-280.

Nikolova V., Nikolov I., Andreev P., Najdenov V., Vitanov T. J. Appl. Electrochem. 2000. V. 30. P.705-710.

Li S., Zheng Y., Qin G.W., Ren Y., Pei W., Zuo L. Talanta. 2011. V.85, No.3. P.1260-1264.

Paracchino A., Brauer J.C., Moser J.E., Thimsen E., Graetzel M. J. Phys. Chem. C. 2012. V. 16, No. 13. P.7341-7350.

Ahuja T., Mir I.A., Kumar D., Rajesh D. Sens. Actuator. B: Chem. 2008. V.134. P.140-145.

Strehlitz B., Grundig B., Kopinke H. Anal. Chim. Acta. 2000. V. 403. P.11-23.

Luo Y.C., Do J.S. Biosens. Bioelectron. 2004. V.20, No.1. P. 15-23.

Hirai T., Kuwabata S., Yoneyama H., J. Electrochem. Soc. 1988. V.135, No.5. P.1132-1137.

Stasyuk N., Smutok O., Gayda G., Gonchar M., Koval’chuk Y. Biosens. Bioelectron. 2012. V.37. P. 46-52.

Ma X., Li G., Wang M. Cheng Y., Bai R., Chen H. Chem. Eur. J. 2006. V.12. P.3254-3260.

Bard A.J., Faulkner L.R. Electrochemical Methods: Fundamentals and Applications –

New York: J. Wiley and Sons, 2000. – 285 s.

Genies E.M., Boyle A., Lapkowski M., Tsintaris C. Synth. Met. 1990. V.36. P.139-182.

Published

2012-12-03

How to Cite

Amperometric chemosensors for ammonium ions detection. (2012). V. N. Karazin Kharkiv National University Bulletin. Chemical Series, 21, 258-263. https://doi.org/10.26565/2220-637X-2012-21-28